WoodMaster CleanFire EPA Outdoor Wood Boiler - Discontinued — Brochure
WoodMaster · Brochure · PDF, 4.0 MB
About the WoodMaster CleanFire EPA Outdoor Wood Boiler - Discontinued
THIS PRODUCT HAS BEEN DISCONTINUED, THIS PAGE IS FOR INFORMATIONAL PURPOSES ONLY
The CleanFire Outdoor Wood Boiler Burns hotter - Cleans easier - Lasts longer.
The New CleanFire EPA Outdoor Wood Boiler produced by WoodMaster is a revolutionary design with a Dry Fire Chamber (DFC) technology. The CleanFire 400 Wood Boiler is ASME Certified and UL listed.
WoodMaster’s CleanFire uses a dry fire chamber to provide hotter, more efficient heat that requires minimal effort to maintain.
- No ceramics
- No damaging corrosion
- No creosote build-up
EPA Approved and meets 2020 NSPS Wood Boiler Standards. Patent-pending design changes heating from the inside out.
- The Dry fire Chamber- (DFC) because it is not water cooled, does not have creosote buildup (ash, moisture, smoke) which sticks to the walls of a water cooled fire chamber, is damaging to the steel and almost impossible to clean out. It is also ceramic free, which in most cases are consumable parts and likely will trap creosote behind them, which is even harder to clean, causing early failure. It has no water corrosion possibility, hugely unlike a typical Hydronic Heater. The DFC does not clinch the flame, creating a hotter fire and a cleaner furnace, the DFC eliminates these problems. Cleaning the fire chamber at the end of the season takes only a few minutes and can be done with a small hand broom. So No ash corrosion No water corrosion, a breeze to clean, how nice is that?
- The CleanFire, (CF) ASME-H stamp pressure vessel stage 1 and 2 boilers do not allow air into the system. An open system always has air in the system, which generates corrosion and likely sludge, sludge settles on the steel and corrosion is underway. The most common way to fight this is with chemicals but over time corrosion wins. Install an Auto Fill to our CF and never have to worry about getting low on water. Closed pressurized systems can be commonly found 40 to 50 years old and still in good condition.
- The Exclusive WoodMaster Control, designed by WoodMaster and only for WoodMaster, reads the heat load you are using and controls the burn rate to that need. (Modulating) This eliminates the cycling on/off that most outdoor stoves use. Cycling unit’s burn hard to recover the water temp and then shut down and smolder for some times hours before starting up again. All these off cycles/smoldering, coats the heat exchanger with unburned fuel making them susceptible to corrosion and less efficient. The Exclusive Control has many safety features, all protecting the operation of the furnace, yet maintaining a constant heat output to your heating needs, spring, fall or winter. It will allow you to set your boiler temp, from 140 to 200 degrees F, night light on/off time and it displays water temp, boiler pressure, Catalyst temp and is extremely easy to use, it can also be internet connected.
Specifications
Photos






Need help with this?
We have sold and serviced these appliances since 1999. If you need a part or advice, call us.
406-300-1776More from WoodMaster
- Owner's Manual – AFS 1100 WoodMaster Pellet Boiler/Furnace -
- Owner's Manual – AFS 900 WoodMaster Pellet Boiler/Furnace - D
- Owner's Manual – WoodMaster Biomass Wood Pellet Mini Boiler -
- Manual – Woodmaster CleanFire 300 Outdoor Wood Furnac
- Brochure – Woodmaster CleanFire 300 Outdoor Wood Furnac
- Warranty – Woodmaster CleanFire 300 Outdoor Wood Furnac
- Brochure – WoodMaster Biomass Wood Pellet Mini Boiler -
- Owner's Manual – Ultra Series WoodMaster Pellet Boiler/Furnac
- Ash Removal – WoodMaster Commercial Pellet Boiler - Discon
- Brochure – Woodmaster Maxim M255 PE - Not Available
- Owner's Manual – Woodmaster Maxim M255 PE - Not Available
- Brochure – 5500 WoodMaster Outdoor Wood Boiler/Furnace